IEC 61111:2009 electrical insulating rubber mats- GlobaVolt

Prioritizing workplace safety in industries all over the world

Duratuf GlobaVolt are globally recognized and used in core industries worldwide to ensure workplace safety. These electrical insulating mats provide non-conductive barriers and prevent current flow through unintended paths during an electrical hazard.

What is Duratuf GlobaVolt?

GlobaVolt complies with the IEC 61111:2009 safety mat standard set by the International Electrotechnical Commission.These electrical insulating mats are made of high-quality elastomer and premium-grade compounds that enhance their insulation properties and mechanical strength. The IEC 61111:2009 electrical rubber mat specification list has five classes, including Class 0 (1 kV), Class 1 (7.5 kV), Class 2 (17 kV), Class 3 (26 kV), and Class 4 (36 kV).

Electric shocks, electrocution, arc flashes, and other electrical accidents keep getting highlighted in the news headlines. These tested mats offer protection in such cases.

Technical Specification

Material Composition Mechanical Puncture Resistance (min) Slip Resistance (min) Ageing Properties at 70±2°C for 168 hours Flame Retardance Low Temperature Test at – 25±3°C Acid Resistance Oil Resistance Working Temperature
Elastomer free from any insertion. Typically, a combination of natural rubber and other synthetic polymers. 70 N 50 N Mechanical Puncture Resistance not less than 80% of original value Does not catch fire No visible tear, cracks or breaks Mechanical Test Values not less than 75% of original value Mechanical Test Values not less than 75% of original value -25°C to 55°C Note: ± 10% on thickness, ± 2% on length & width

Stock Roll Size

Product Code (SKU) Class Colour Anti-Skid Design Thickness Width Length Weight/Roll
IM-IEC-C0-BLATT-2MM 0 Black Top & Bottom – Textured 2.0 mm 1 M 10 M 32 Kg(s)
IM-IEC-C1-BLATT-2MM 1 Black Top & Bottom – Textured 2.0 mm 1 M 10 M 32 Kg(s)
IM-IEC-C2-BLAFT-3MM 2 Black Top – Fine Ribbed & Bottom – Textured 3.0 mm 1 M 10 M 40 Kg(s)
IM-IEC-C3-BLAFT-4MM 3 Black Top – Fine Ribbed & Bottom – Textured 4.0 mm 1 M 10 M 56 Kg(s)
IM-IEC-C4-BLAFT-5MM 4 Black Top – Fine Ribbed & Bottom – Textured 5.0 mm 1 M 10 M 72 Kg(s)

Customize Your Mat

Customisation Options
Thickness Thickness can be customised for different classes upto 14 mm as per customer’s requirement
Width Max. width upto 1220 mm (4 ft)
Length Max. length upto 15 m (50 ft)
Color Dark Grey or any other colour subject to techno-commercial feasibility
Anti-skid Design Also available in Top & Bottom side texture design in all classes

Maximum Voltage

Product Code Class Max Use Voltage AC Proof Voltage Withstand Voltage Max Thickness Allowed Recommended Thickness
IM-IEC-C0 0 1.0 kV 5.0 kV 10.0 kV 6.0 mm 2.0 mm
IM-IEC-C1 1 7.5 kV 10.0 kV 20.0 kV 6.0 mm 2.0 mm
IM-IEC-C2 2 17.0 kV 20.0 kV 30.0 kV 8.0 mm 3.0 mm
IM-IEC-C3 3 26.5 kV 30.0 kV 40.0 kV 11.0 mm 4.0 mm
IM-IEC-C4 4 36.0 kV 40.0 kV 50.0 kV 14.0 mm 5.0 mm

See the Difference Safety Makes

Slide right to discover how Duratuf insulating mats transform your industrial floors into safe, compliant work zones.
Forest Scene
Mountain Scene

Choose Safety. Define Style.
IEC 61111:2009 Insulating Mats in Every Shade of Protection.

Transformer Room

LT Panel

Genarator Room

Data Center

Best Uses of GlobaVolt electrical insulating rubber mats

  • Electrical Substations Substation Control Rooms, Switchyards, etc.
  • Power Plants: Generator and Turbine Areas, Transformer Yards, etc.
  • High Voltage Rooms: Testing Labs, Switchgear Room, Control Rooms, etc.
  • Switchgear Rooms: Distribution Boards, Circuit Breaker Panels, etc.
  • Control Panels: Electrical Cabinets, Variable Frequency Drives (VFD) Cabinets, etc.
  • Data Centers: UPS Rooms, Telecommunication Rooms, Generator Rooms, etc.
  • Battery Rooms: Battery Storage Racks, Battery Charging Stations, etc.
  • Transformer Stations: Cable Trenches, Busbar Areas, Switching Areas, etc.
  • Electrical Laboratories: Circuit Testing Zones, Equipment Testing Zones, etc.
  • Railway Electrification Systems: Signal Equipment Rooms, Overhead Equipment (OHE) Maintenance Depots, etc.

Key Features and Properties IEC 61111 Electrical Rubber Mats for Industrial Uses

Anti-slip surface

They come with a ribbed surface texture to minimize the risk of workers slipping and falling in workplaces.

Flame-retardance

The GlobaVolt mats have self-extinguishing properties, reducing risks during fire hazards.

Color-coded

They come in different color coding on product labels, such as red for Class 0, white for Class 1, yellow for Class 2, green for Class 3, and orange for Class 4.

Resistant to a wide temperature range

They are suitable for working temperatures ranging from -25 degrees to +55 degrees centigrade.

Why Choose GlobaVolt IEC Electrical Insulating Rubber Mats

Quality-assurance

They are tested, certified, and compliant mats available at a competitive IEC 61111:2009 electrical insulating mats price.

Customer-tested

These electrical insulating rubber mats have positive reviews and ratings across e-commerce and social media platforms.

Sales support

Duratuf offers high-end pre-sales and post-sales support to resolve any queries within a short span of time

Timely delivery

The GlobaVolt electrical mats are shipped and delivered on time by an efficient supply chain team.

Ready to Increase Your Business Productivity?

Explore change with Duratuf rubber sheets- chosen and recommended by experts from your industry

Customer testimonials and success stories

Take a look at what our customers think and say about us

Google Review Logo
Procurement Manager

FAQs

Duratuf GlobaVolt complies with the IEC 61111 standard and was last updated in the year 2009.

Five voltage classes are available in Duratuf GlobaVolt mats from class 0 to 4. Each voltage has different working voltage suitability, dielectric strength, AC-proof voltage, and standard thickness.

Yes, these mats have flame retardance as well as anti-slip properties, ensuring overall protection in the workplaces, protecting people from fire hazards and physical accidents.

For your specialized application area, you can use customized insulating mats. With customization, you can tailor-make the mats as per your required dimensions.

You should regularly visually inspect your IEC 61111:2009 electrical insulating mats. Make sure to clean them and avoid using harsh chemicals, excessive physical stress, and others. Reach out to us for detailed guidelines.

We have been leading the industry for more than 15 years. In addition, we ensure workplace safety of core industries of the world with our premium quality electrical safety mats.