IS 15652:2006 Certified Electrical Rubber Mats- Duratuf Xvolt

Offer high-voltage electrical safety at industrial workplaces

Duratuf Xvolt is an industrial-grade IS 15652:2006 certified electrical rubber mats manufactured to provide high-voltage electrical safety and long-term performances in industrial applications. XVolt electrical safety mats are available in three major categories like class A, class B & Class C with maximum use voltages up to 33 kV and dielectric strength up to 65 kV, making them suitable for a wide range of electrical installations across industries.

What is Duratuf XVolt Electrical Insulating Mat?

Duratuf XVolt is a high-performance IS 15652:2006 certified electrical rubber mat designed to provide a reliable insulation barrier between electrical equipment and personnel working in high-voltage areas. It is manufactured using premium-grade elastomers to ensure superior electrical resistance, mechanical strength and long-term durability in industrial applications.

XVolt electrical rubber mats are designed to minimize the risk of electric shock by preventing current leakage to the ground. Available in Class A, Class B, and Class C, XVolt insulation mats are suitable for different voltage levels up to 33 kV, making them ideal for use in substations, switchgear rooms, control panels, transformer yards and other critical electrical areas.

Additionally, Our XVolts insulation mats feature an anti-skid surface design, enhancing workplace safety by reducing slip and trip hazards in operational zones.

Technical Specification

Technical Specifications of the XVolt Insulation Mats
Material Composition Tensile Strength (Min.) Elongation at Break (Min.) Leakage Current (Max.) Insulation Resistance With
Water When Tested At 5000 V (Min.)
Flame Retardance (Max.) Aging Properties At 70 ± 1°C For 168 Hours Acid, Alkali & Oil Resistance Working Temperature
Elastomer free from any insertion 15N/mm2 250% 10 mA 1,00,000 MΩ Extinguishes Within 5 Secs T.S & E.B Not Less Than 75% Of Original Value T.S & E.B Not Less Than 80% Of Original Value -10°C To 55°C

Stock Roll Size

Product Code (SKU) Class Colour Anti-Skid Design Thickness Width Length Weight/Roll
IM-XV-CA-BLADOT-2MM A Black Top – Dotted & Bottom – Textured 2.0 mm 1 M 10 M 35 Kg(s)
IM-XV-CB-BLADOT-2.5MM B 2.5 mm 42 Kg(s)
IM-XV-CC-BLADOT-3MM C 3.0 mm 49 Kg(s)
IM-XV-CA-BLUDOT-2MM A Blue 2.0 mm 35 Kg(s)
IM-XV-CB-BLUDOT-2.5MM B 2.5 mm 42 Kg(s)
IM-XV-CC-BLUDOT-3MM C 3.0 mm 49 Kg(s)
Also available in 1M width x 2M Long cut sizes in ready stock.

Maximum Voltage

Product Code Class Max Use Voltage AC Proof Voltage Dielectric Voltage Standard Thickness
IM-XV-CA A 3.3 kV 10.0 kV 30.0 kV 2.0 mm
IM-XV-CB B 11.0 kV 22.0 kV 45.0 kV 2.5 mm
IM-XV-CC C 33.0 kV 36.0 kV 65.0 kV 3.0 mm

Customize Your Mat

Customisation Options
Width Max. width upto 1500mm
Length Max. length upto 50M
Color Red, Grey, Green, Yellow or any other colour subject to techno-commercial feasibility
Cut Length, Custom Shapes and Colors are Available upon Request.
Note: Manufacturing Tolerance Of +/- 10% On Thickness, +/- mm On Width And Length Up To 600 mm And +/- 20 mm For Higher.

See the Difference Safety Makes

Slide right to discover how Duratuf insulating mats transform your industrial floors into safe, compliant work zones.
Transformer Room
Transformer Room with IS 15652 Electrical Insulating Mats (Blue)

Color Range
Choose Safety. Define Style.
Xvolt Insulating Mats in Every Shade of Protection.

Transformer Room

LT Panel

Genarator Room

Data Center

Common Uses of IS15652 Insulating Mats for Workplace Safety

Duratuf XVolt electrical insulating mats are common in high-voltage application areas of the industries. They are installed in the following areas:

  • HT/LT Panels
  • Switchgear & Switchboards
  • Transformer Rooms
  • Generator Rooms
  • Lift rooms
  • Bus Bar Areas
  • Control Panels & VFD Panels
  • Data Centers & UPS Rooms
  • Electrical Substations and Testing Labs
IS 15652 Electrical Insulating Mats Application

Top Features or Properties of XVolt Insulating Mats

Duratuf XVolt is manufactured to deliver consistent electrical safety, compliance, and long-term value for industrial applications where reliability is critical. Designed as per IS 15652:2006 standards, XVolt mats help businesses minimize electrical risks while ensuring operational continuity.

IS 15652:2006 Certified Safety

Manufactured and tested to meet Indian electrical safety standards, ensuring compliance in high-voltage environments

High Voltage Protection

Available in Class A, B, and C, suitable for installations up to 33 kV across diverse industries

Durable Industrial-Grade Construction

Made from premium elastomer for superior insulation, mechanical strength, and extended service life

Anti-Skid & Flame-Retardant Design

Enhances workplace safety by reducing slip hazards and minimizing fire risks during electrical faults

Ready Stock & Faster Delivery

Large inventory ensures quick dispatch and reduced downtime for ongoing projects

Expert Support & Custom Solutions

Technical guidance and customization options to match specific application requirements

Why Choose Duratuf for Electrical Rubber Matting

Our product quality is not just a promise but a commitment.

Brand Reputation

Proud 'Made in India'—'Made for India product'

Reviews and Rating

3793+ happy customers worldwide with 4.8 Google Rating for service

Ready Stock

10,000 sq m ready stock in warehouses allover India

Sales Support

Product selection guidance to after-sales queries

Ready to Increase Your Business Productivity?

Explore change with Duratuf rubber sheets- chosen and recommended by experts from your industry

Customer testimonials and success stories

Take a look at what our customers think and say about us

Frequently Asked Questions: XVolt Electrical Insulating Mats - IS 15652:2006

Duratuf XVolt electrical insulating mats comply with the IS 15652:2006 standard. This standard has been set by the Bureau of Indian Standards (BIS) and has been updated in the year 2006.

The IS 15652 electrical rubber mat specification list includes three classes- Class A (3.3 kV), Class B (11 kV), and Class C (33 kV).

Yes, Duratuf XVolt mats have flame retardance property and extinguishes within 5 seconds. In addition, they have an anti-skid property as they come in a dotted surface texture.

We understand that your application area may require specialized sizes of electrical mats. You can tailor-make the IS 15652 rubber mat as per your required dimensions for your application area.

Keep your mats clean and get rid of dust, dirt, moisture, and greases. Besides, you should avoid subjecting them to extreme temperatures, harsh chemicals, and excessive physical stress. Immediately repair or replace the insulating mats whenever you see any damage. Reach out to our experts for a detailed maintenance guideline.

If you are looking for quality-assured IS 15652 2006 certified electrical insulating mats in India, you should choose Duratuf XVolt mats. They undergo rigorous quality control and comply with the industrial standards.